An important aspect of food-grade material approvals is exposure time. There are a few levels which are important, and depending on the exposure levels, short term genotoxicity tests like the Ames and mouse lymphoma assay MLA tests may be required. Or for higher exposure, full in vivo testing in lab animals may be required. Additionally, the structure of the molecules in question can be analyzed and modeled for structure-activity relationships.
In short, an analysis is required to determine if the material contains any structures or properties which can potentially damage DNA. These kinds of analysis are particularly valuable where the compound is untested or unknown.
To be fully FDA compliant, food-grade materials must be approved for the specific conditions they are operating in, as well as the materials they are in contact with—i. In addition, the material needs to withstand any cleaning processes used.
These can have an effect on the ability of the material to leach into a material it comes in contact with. If your medical device comes in contact with a patient, all of the above is insufficient. While there are a few similarities, biocompatibility is focused on risks and is a risk-based approach. Medical Packaging.
Durable Medical Equipment. Medical Fabrics. Wearable Devices. Product Finder Search Search. First Name. Last Name. Contact Us Today The team at Entec will work with you through every stage of the process to realize your project goals. The agar layer acts as a cushion to protect the cells from mechanical damage while allowing the diffusion of leachable chemicals from the polymeric specimens.
Extracts of materials that are to be tested are applied to a piece of filter paper. This test is designed for materials in a variety of shapes.
The procedure allows for simultaneous extraction and testing of leachable chemicals from the specimen with a serum-supplemented medium. The procedure is not appropriate for very low- or high-density materials that could cause mechanical damage to the cells.
The procedure allows for extraction of the specimens at physiological or non-physiological temperatures for varying time intervals. It is appropriate for high-density materials and for dose-response evaluations. For a more restrictive classification, there are materials that require the ISO testing [6], that includes assays that can be seen in the Figure 4. Although some tests overlap, the minimum requirements for testing are usually different.
It does not define how well equipment will perform in an autoclave or when exposed to SIP because humans are not generally steamed in place. Another thing biocompatibility is not is simple. ISO is a part standard that evaluates the effects of medical device materials on the body. The rest of the sections mostly deal with appropriate methods to conduct the biological tests suggested in Part 1.
ISO uses matrices to break medical devices down into three categories: Surface, External Communicating, and Implant and further breaks these categories into subcategories based on exposure time limited, prolonged, and permanent.
Once we identify the device category and exposure time, we can then use the ISO standard to select a recommended biologic testing protocol.